Product Overview
Siemens 547-321A,
Siemens, SRCM Room Condition Monitor, RCM FM BAC +/-.05WC(12.5PA)0.5%FS
The SRCM, Siemens Room Condition Monitor, is a touch screen, flush mounted monitor that is typically located outside of a pressurized room, such as an Operating Suite or Isolation Room. In a hospital, laboratory, or animal research facility, the integrity of the ventilation control system is at the heart of a contaminant-free environment. Whether a room is to be maintained at a negative pressure to prevent contaminants from escaping into adjacent areas or positive pressure to protect patients with compromised immune systems, the proper pressurization of the room is essential. To assure proper pressurization is maintained in these critical environments, a room pressure monitor is employed to measure and alert staff and personnel of any change in pressure - no matter how small. A fail-safe solution to monitoring these very low pressure changes is the Model SRCM Room Condition Monitor, which uses highly accurate capacitance sensing technology to measure and display true low pressure differential to a resolution of 0.00001. in water column (WC).
Item Specifications
-
Features
Functions
Benefits
- High resolution color touch-screen displayImmediate feedback on room status
Intuitive graphic interface - Two-in-One eliminates the need for a second monitorDisplay both pressure and room condition
On-board and remote sensing capabilityReduced costs - Flush-mount designNo visible mounting fasteners
Snap-in flush bezel
Face is sealed for cleaning or wipe-down - True pressure measurementHigh accuracy low differential capacitance technology
Dead ended solution
Standard on-board sensor and optional remote sensorHigh accuracy
No contamination or clogging
two measurements in one
Measure very low pressure changes - Ease of installationMounts in off-the-shelf electrical gang box
Four-screw, self-leveling mount
Labeled, removable termination stripsEase of installation - Clone ConfigurationDisplay rotates up for acceSS to USB port
Cloning of configurations for multiple unit installation via USB portEfficient setup for common RCM's - Setup Display BannerUser Defined Text for flexible room name
Room Status: Change room from Isolation to No IsolationCustomized to every installation/room
Local acceSS for fast room type change - Setup Display Advanced DisplayDisplay Contrast
Display Averaging Display pressure Enable passwordChange brightneSS of display
Improve display resolution in unstable ambient pressure environments
Display primary and secondary or toggle between 2 rooms
Administrator and Supervisor available. - Setup Unit OperationSetup primary and secondary room
Change analog output
Free form data entry for room nameFlexible setup
Flexible IO
Flexible room naming - Multiple Communications OptionsBACnet MSTP
Siemens P1Flexible to meet the installation requirements - Alarm capabilitiesLocal audible and visual alarming
Remote annunciator alarming capability
Alarm delay featureFlexible Monitoring
Remote monitoring
Prevent nuisance alarms - Multiple Room SupportThe SRCM can be used to display the status of two rooms.
Second pressure sensor is required
Physical Description
Case Fire retardant plastic UL94 V-0
Electrical connection Removable terminal block
pressure fittings Barbed fittings for 1/4 tubing
Mounting Mounts to triple gang, double-deep electrical box
Technical Data
Dimensions: 5.84 H x 7.45 W x 0.38 D (14.84 cm x 18.92 cm x 0.95m)
Weight: 1 lb 3.2 oz (554 grams)
Power:
Operating Range: 18 to 32 VACbr /> Consumption: 10W maximum, 3 W typical
Communications: BACnet MS/TP (9600, 19200, 38400, 7680 Baud Rates)
Inputs:
1 internal pressure sensor
2 A/D's inputs for remote pressure sensors, temperature or humidity sensors (Resolution 16-bit)
Door contact dedicated
Certifications
- CE Mark