Product Overview
Mars Air Curtain PH1048-1UA-PW Overview
The Phantom Series is the choice for architects and designers who need all the performance and protection of a Mars Air Curtain, but need the unit to blend in with the building's internal or external aesthetics. Our Phantom units feature the same top-performing internal components as our 1/2 HP Standard Units, but are enclosed in housing which can be concealed and recess-mounted into a ceiling. The units are quieter and less conspicuous, without sacrificing anything in their ability to do the job required. Standard color for the Phantom Models is Pearl White and heated options are available.Product Features of PH1048-1UA-PW
- Corrosion Resistant Powder Coated Finish
- Durable Metal Construction
- Durable metal design
- Easy To Install
- Environmental Protection: 10
- Freight included
- Made in USA
- Motor fan assembly
- Recessed in ceiling
- Sleek metal design
- Standard color: Pearl White
- 1/2 hp direct-drive motor
PH1048-1UA-PW Specifications
- Voltage: 115V
- FLA (Ampacity): 5.1Amps
- Door Width (Inches): 48
- Door Height: 10'
- Number of Poles: 1
- Max Volume: 2550
- Max Velocity 2550
- Frequency (Hertz): 60
- # of Motors: 1
- Sound dBA: 66
- Weight (lbs): 65
- Color: Pearl White
PH1048-1UA-PW Accessories
DOOR SWITCHES
Automatic on/off control of air curtain as door is opened and closed
Line Voltage
- 99-014 Door Limit Switch - Combination roller and plunger - 20 amps, 250v, or 1 hp max.
24-Volt Control
- 99-018 Commercial Magnetic Reed Switch Only - Plastic | Surface-mounted | NOTE: Used with control packages for double doors
- 99-124 Industrial Floor-Mounted Magnetic Reed Switch Only - Floor-mounted | NOTE: Control panel required
- 99-125 Industrial Surface-Mounted Magnetic Reed Switch Only - Surface-mounted | NOTE: Control panel required
CONTROL PACKAGES
Combination packages of door switches, controllers, time delays, and thermostats
Line Voltage
- 99-063 Analog Thermostat - Remote-mounted
- 99-064 Analog Thermostat DPST - Double pole, single throw | Acts as heat on demand | Remote-mounted
24-Volt Control
- J0021 Commercial Magnetic Reed Switch with Controller and Adjustable Time Delay | 115v, 6 sec. - 20 min. | Plastic | Surface-mounted
- J0022 Commercial Magnetic Reed Switch with Adjustable Time Delay |208-230v 1?, 6 sec. - 20 min. | Plastic | Surface-mounted
- J0023 Commercial Magnetic Reed Switch with Controller | 115v, Plastic | Surface-mounted
- J0024 Commercial Magnetic Reed Switch with Controller | 208-230v 1?, Plastic | Surface-mounted
- J0028 Door Limit Switch with Controller and Adjustable Time Delay |115v, 6 sec. - 20 min. | Surface-mounted
- J0029 Door Limit switch with Controller and Adjustable Time Delay |208-230v 1Φ - 6 sec. - 20 min. | Surface-mounted
- J0034 Door Limit Switch with Adjustable Time Delay, 1 sec. - 17 min. | Surface-mounted | NOTE: Control panel required
- J0036 Industrial Magnetic Reed Switch with Controller | 115v, Surface-mounted
- J0037 Industrial Magnetic Reed Switch with Controller | 208-230v 1Φ - Surface-mounted
- J0038 Industrial Magnetic Reed Switch with Controller and Adjustable Time Delay | 115v, 6 sec. - 20 min. | Surface-mounted
- J0039 Industrial Magnetic Reed Switch with Adjustable Time Delay | 115v, 1 sec. - 17 min. | Floor-mounted | NOTE: Control panel required
- J0040 Industrial Magnetic Reed Switch with Adjustable Time Delay, 1 sec. - 17 min. | Surface-mounted | NOTE: Control panel required
- J0042 Industrial Magnetic Reed Switch with Controller and Adjustable Time Delay | 208-230v 1Φ - 6 sec. - 20 min. | Surface-mounted
FILTERS
- STD2-FILTER-[size] STD2 Aluminum Mesh Filter 1/4’ Internal-mount | Set of 2 | [size]: Specify size in inches
MOTOR CONTROL PANELS
Remote-mounted control panels for all 3Φ units and 1Φ units when greater than 1 hp (NEMA 1) | Units come standard with HOA (hand/off/auto) switch | Panel shipped loose | Standard color Battleship Gray | NOTE: Electric heated units include internal control panel and remote-mounted 24v thermostat with heat/off/fan only switch [vc] Voltage codes: A = 115/1/60 D = 208-230/1/60 G = 208-230/3/60 H = 460/3/60 U = 220/1/50
- MCPA-1U 1-Motor Control Panel ½ hp | Unheated
- MCPA-2U 2-Motor Control Panel ½ hp | Unheated
- MCPA-3U 3-Motor Control Panel 1/2 hp | Unheated
- MCPA-4U 4-Motor Control Panel 1/2 hp | Unheated
- MCPA-5U 5-Motor Control Panel 1/2 hp | Unheated
- MCPA-6U 6-Motor Control Panel 1/2 hp | Unheated
- MCPA-1V 1-Motor Control Panel 1/2 hp | Steam/ Hot Water Heated
- MCPA-2V 2-Motor Control Panel 1/2 hp | Steam/ Hot Water Heated
- MCPA-3V 3-Motor Control Panel 1/2 hp | Steam/ Hot Water Heated
- MCPA-4V 4-Motor Control Panel 1/2 hp | Steam/ Hot Water Heated
- MCPA-5V 5-Motor Control Panel 1/2 hp | Steam/ Hot Water Heated
- MCPA-6V 6-Motor Control Panel 1/2 hp | Steam/ Hot Water Heated
PANEL ADD-ONS
- 94-013 Adjustable Time Delay, 1 sec. - 17 min. | NOTE: Control panel required
- 99-165 Non-fused disconnect | 32 amps, Panel-mounted
- 99-164 Non-fused disconnect | 63 amps, Panel-mounted
- 99-114 Fused disconnect | 32 amps, Panel-mounted
- 99-115 Fused disconnect | 63 amps, Panel-mounted
- MCP-MTD Factory-Mounted Motor Control Panel
- HL2SPD 2-Speed Motor with Switch Off/Lo/Hi | Panel-mounted switch | NOTE: if 460v power is specified, a separate 115v or 208-230 1Φ service is required
- MSLAV Master/Slave Control with Single Thermostat
MULTI-SPEED CONTROL OPTIONS
- 99-003 3-Speed Remote switch | 25 amps, Off/Lo/Med/Hi | Up to 1 hp 1Φ
- 99-033 2-Speed Remote Switch | 15 amps, Off/Lo/Hi | Up to 1 hp 1Φ
- 99-034 2-Speed Remote Switch | 25 amps, Off/Lo/Hi | Up to 1 hp 1Φ